Small burner
Testing the flammability of building materials using a single flame test in a small burner in accordance with EN ISO 11925-2 and DIN 4102-1

750°C DIN oven
Testing the non-combustibility of building materials at 750°C in a DIN oven in accordance with DIN 4102-1

XP2 smoke development test
Determination of smoke development from materials under flame exposure in accordance with Annex B of DIN 4102-1

DIN smoke test
Determination of smoke development from materials under smoldering conditions in accordance with Annex A of DIN 4102-1

Fire test ISO furnace
Testing the fire behavior of building materials in an ISO furnace in accordance with EN ISO 1182:2020
Fire shaft
Investigation of the fire behavior of components in a fire shaft in accordance with DIN 4102-16
Determination of the tendency to smolder
Testing the smoldering behavior of building materials in accordance with EN 16733

Muffle furnace
Determination of the organic content in building materials; e.g. mineral wool according to EN 13820 at 500°C or wood wool at 750°C